Fire protection for Calgary property managersEvery building, every device, one contractor.
Most Calgary buildings need a yearly fire alarm test to CAN/ULC-S536, yearly extinguisher service, emergency lights tested every year, and sprinklers and backflow tested every year. We keep a list of every unit and every device across your buildings, book the visits together, and send you one set of reports instead of a pile of invoices from different companies.
- Multi-site inspections booked in one trip
- Visits scheduled around your tenants and hours
- Full reports for the Calgary Fire Department and your insurer
- Kidde
- Badger
- Amerex
- Buckeye
- ProTex II
- CaptiveAire
- Autocall
Which fire protection inspections does a Calgary building need, and how often?
For most commercial and residential buildings: the fire alarm, extinguishers, emergency lighting, sprinklers and backflow are all yearly, with monthly checks your site staff can do in between. If a tenant runs a commercial kitchen, its hood system adds a six-month visit.
| System | How often | Usually whose responsibility |
|---|---|---|
| Fire alarm system (CAN/ULC-S536) | Yearly | Building owner |
| Sprinklers and standpipes (NFPA 25) | Yearly, plus periodic checks | Building owner |
| Backflow preventer (CSA B64.10) | Yearly, results submitted to the City | Building owner |
| Emergency lights and exit signs | Monthly check, yearly test | Building owner |
| Portable fire extinguishers (NFPA 10) | Monthly check, yearly service and tag | Owner in common areas; often the tenant inside a unit |
| Kitchen hood suppression in a restaurant unit | Every 6 months | Often the tenant |
Who pays for what is set by each lease, not by us. Intervals can change with equipment type, occupancy and the Calgary Fire Department; we confirm the real schedule for each building on the first visit. Full intervals table →


Why one fire protection contractor for the whole portfolio?
Because the problems hide between contractors: the alarm company blames the sprinkler company, nobody owns the tie-in, and three sets of reports land in three inboxes on three schedules. With us there's one schedule, one report set and one number to call.
One trip, several sites
Send us the addresses. We group buildings that are close together and book them on the same run, so your on-site staff aren't meeting a technician every other week.
A list of every unit and device
We keep a record per building and per suite of what's installed: alarm devices, extinguishers, exit signs and emergency lights. When a tenant moves out or a suite is renovated, you know what was there.
One set of reports
A full CAN/ULC-S536 report for the alarm, not just a certificate, plus extinguisher and lighting records, together per building. Ready for the fire inspector, your insurer or a board meeting.
Sprinklers and backflow without a second vendor
We book sprinkler, standpipe, hydrant and backflow testing through our partner network and report on it, so you still only deal with us. How that works →
Deficiencies fixed fast
Each deficiency is photographed and quoted line by line, so you can approve repairs before the fire department's reporting window closes.
Lockbox upgrades
The Calgary Fire Department is requiring existing lockboxes to be upgraded. We upgrade existing CFD lockboxes and install new ones where required.
Get one quote for all your buildings
Upload the building list you already have: a spreadsheet, a PDF, even a photo of a printed list. Or paste the addresses. Tick what you need and we'll quote every site together, with nearby buildings grouped into the same visits.
- CSV, Excel (.xlsx), PDF or a photo, up to 4 MB
- Up to 300 buildings in one request
- Building names, units and floors help, but addresses are enough
- A written quote within one business day, usually the same day
Rather email it? Send it to info@defensefirepro.com with "Multi-site quote" in the subject.
What happens if an inspection finds deficiencies in my building?
You get a written list and a quote for each item, and the clock starts: in Calgary, fire alarm service companies have to report unrepaired deficiencies to the fire department, and the CFD expects them within 10 days of the inspection.
The National Fire Code – Alberta Edition says that when the person maintaining fire protection equipment finds it inoperative or defective, and the owner won't or can't fix it, they must notify the fire department and the owner in writing. A Fire Safety Codes Officer then follows up with the owner and asks for documentation that the repairs are done.
For a property manager that means two things: approve deficiency repairs quickly, and keep the full inspection report on site for at least two years. An annual certificate alone isn't accepted as proof. Read how deficiency reporting works in Calgary →
Deficiencies must be fixed; recommendations on the same report are optional. If you act on a recommendation, it has to be done to code and is maintained at every inspection after that.
Short-term rentals and small landlords
One suite or a handful of doors gets the same care as a tower. We supply ULC-listed extinguishers from our showroom, mount and tag them, and give you dated documentation you can show an insurer or keep with your listing records.
- Extinguishers matched to the space, picked up at 6560 2 St SE, Calgary, AB T2H 1J4 or installed on site
- Only ULC-listed units: U.S.-only extinguishers, aerosol cans and fire balls aren't approved in Alberta (why)
- Annual service at $12 per extinguisher when you bring them in
Our technicians at work
Real photos of our Calgary team on the job: installs, inspections and panel builds.






Put your buildings on a compliance calendar
Tell us when each building's alarm, extinguishers and lights were last inspected. We'll remind you a month before each one is due.
Property manager fire protection questions
In a leased space, is fire equipment the tenant's or the landlord's responsibility?
Your lease decides. Building systems like the fire alarm and sprinklers usually sit with the owner, while equipment inside the unit, like a kitchen hood suppression system and extinguishers, is often the tenant's. We can inspect for either party and send the report to both.
Can you inspect several of our buildings in one visit?
Yes. Send us the list of addresses and what's in each building, and we'll book nearby sites on the same trip and send one set of reports. For more than 40 extinguishers or several buildings, ask about an annual inspection agreement.
How much does a fire alarm inspection cost for a Calgary building?
A typical annual fire alarm inspection costs $500 to $700 before GST, based on our own quotes, and deficiency repairs typically run $725 to $975. The final price depends on the building and the number of devices, and you get a written quote first. Get a price range →
Do you install or upgrade Calgary Fire Department lockboxes?
Yes. The Calgary Fire Department is requiring existing lockboxes to be upgraded, and we upgrade existing CFD lockboxes and install new ones where required.
Can you take over from our current fire protection company?
Yes. Send us the last inspection reports and the dates on the current tags for each building. We'll check the systems, document open deficiencies with photos, and set up one schedule so nothing lapses in the switch.
Do you cover buildings outside Calgary?
Yes. Along with Calgary we look after buildings in Airdrie, Chestermere, Cochrane and Okotoks; those sites may add a small travel charge. Sites elsewhere in Alberta are quoted separately.
More answers in the working with us FAQ.
Related pages for building owners
Fire alarm inspection
Annual CAN/ULC-S536 inspection, a full report for the Calgary Fire Department, and deficiency repairs.
Learn more →Emergency lighting & exit signs
Yearly duration tests by a technician, plus the monthly check you can do yourself, with failed packs replaced on the same visit.
Learn more →Sprinklers & backflow
Annual sprinkler, standpipe, hydrant and backflow testing booked and reported through us, so you deal with one company.
Learn more →Your fire alarm company has to report unrepaired deficiencies to the Calgary Fire Department
In Calgary, fire alarm service companies must report deficient systems to the fire department, and the CFD expects it within 10 days. What that means for building owners, and why a certificate isn’t enough.
Learn more →Send us your buildings
List the addresses, what's in each one and when it was last inspected. Attach your last reports if you have them. We reply within one business day, usually the same day.
- Written quote before any work
- Photos of every deficiency
- We book your next inspection and remind you