Autocall fire alarm systems in CalgaryAddressable panels that pass verification.
Defense Fire Protection is an authorized Autocall distributor. We design, install, program, verify and inspect Autocall addressable fire alarm systems for Calgary offices, schools, restaurants, retail, warehouses and multi-building sites. Every fire alarm needs a CAN/ULC-S536 inspection at least once a year, and new or modified systems are verified to CAN/ULC-S537. Installs are quoted in writing from your drawings or a site walk.
- Autocall is a Johnson Controls fire detection brand
- Panels from 250 to 3,000 addressable points
- One company for your alarm and your suppression tie-in


- Kidde
- Badger
- Amerex
- Buckeye
- ProTex II
- CaptiveAire
- Autocall
Why choose an Autocall fire alarm system?
Because every device is individually supervised, wiring costs less, annual testing is faster, and the panel can grow with the building. Your fire alarm control unit is the nerve centre of the building's life safety. Here's what Autocall does better.
Every device individually supervised
Autocall detectors, modules and notification appliances are addressable. The panel watches each device on its own, so it knows exactly which smoke sensor, pull station or horn has a problem, and its settings can be tuned individually.
Lower wiring and installation cost
Addressability allows T-tapping and more efficient wire runs, which can lower installation and overall project costs. Autocall 4100ES units arrive custom-built, assembled and ready to connect.
Easier, faster annual testing
TrueAlarm sensors report "almost dirty" status before they cause nuisance alarms. TrueAlert ES notification appliances can self-test, and device-level ground fault isolation pinpoints wiring faults. Less time on site, less disruption to your tenants.
Controls kitchen & special-hazard suppression
The Autocall 4007ES and 4100ES are listed for multi-hazard suppression release. The 4004R is built specifically for suppression release, with sequences programmed right at the panel. Since we also service six suppression brands, one company handles both systems and the tie-in between them.
Talks to your building systems
With BACnet and Modbus support, Autocall integrates with building management and security systems. A fire event can coordinate elevators, door holders, smoke dampers and air pressurization automatically.
See your system from anywhere
The color touchscreen display works even with gloves. The TrueSite Workstation and TrueSite Mobile Client app let facility managers view reports and system status from a PC or phone, and SafeLINC Cloud connects panels across a campus.
Grows with your building
Autocall's modular design scales from 250 to 3,000 addressable points and networks multiple panels together. A migration path to new features means you upgrade instead of starting over.
Upgrade an old conventional panel without rewiring
The Autocall 4007ES is cross-listed with most conventional detectors and has programmable end-of-line resistors. It can replace an existing conventional panel with minimal cost and disruption, then add addressable devices over time.
Which Autocall fire alarm panel fits your Calgary building?
It comes down to size: the 4007ES for small to mid-size buildings, the 4010ES for mid-size and growing sites, and the 4100ES for large facilities that need voice evacuation.
| Panel | Capacity | Highlights | Best for |
|---|---|---|---|
| Autocall 4007ES | Up to 250 addressable points | Integrated color touchscreen; networkable; multi-hazard suppression release; cross-listed with most conventional detectors | Small to mid-size offices, retail, restaurants, schools, conventional panel upgrades |
| Autocall 4010ES | 250 to 1,000 points | Device-level ground fault isolation; almost-dirty sensor reports; optional touchscreen; IP networking | Mid-size buildings and growing sites |
| Autocall 4100ES | Up to 3,000 points | Integrated voice/audio evacuation (UL 2572 listed for emergency communications); multi-hazard suppression release; large configurable touchscreen; campus networking | Large facilities, high-rises, campuses, hospitals |
| Autocall 4004R | Suppression release panel | Program releasing sequences directly from the panel, no offline tool needed | Electrically released suppression systems |
| Autocall 4006 | 5–10 initiating, 4 notification circuits | Conventional panel with built-in DACT for central station monitoring | Small buildings needing simple, monitored protection |
| Autocall 4003EC | Small voice panel | Emergency voice/alarm communication; can join a campus-wide mass notification system | Smaller buildings needing voice evacuation |
Our Autocall services in Calgary
We cover an Autocall system from design to every annual inspection after it.
- New installs and tenant fit-outs: system design, panel supply, device layout and programming with the Autocall ES Programmer.
- Conventional-to-addressable upgrades: replace aging panels with a 4007ES or 4010ES while reusing compatible field wiring.
- Verification: new and modified systems verified to CAN/ULC-S537 before occupancy.
- Annual inspection and testing to CAN/ULC-S536, with a report for the Calgary Fire Department. See fire alarm inspection in Calgary.
- Suppression tie-ins: kitchen hood and special-hazard systems connected so a discharge sounds the building alarm, as Alberta requires.
- Troubleshooting and repairs: ground faults, trouble signals, failed devices and panel batteries.
One company for your fire alarm and your suppression system
Most Calgary buildings have a fire alarm company and a separate suppression company, and the tie-in between them is where problems hide. We service both, so there's one inspection schedule, one report and one call.
Autocall fire alarm FAQ
Who sells and services Autocall fire alarm systems in Calgary?
Defense Fire Protection, at 6560 2 St SE, is an authorized Autocall distributor. We install, program, verify, inspect and repair Autocall fire alarm systems across Calgary, Airdrie, Chestermere, Cochrane and Okotoks. Call (403) 807-5822.
Who makes Autocall fire alarm systems?
Autocall is a fire detection brand of Johnson Controls. Autocall panels and devices are sold and serviced through authorized local distributors.
What's the difference between the Autocall 4007ES, 4010ES and 4100ES?
Size and features. The 4007ES handles up to 250 addressable points with a built-in touchscreen, ideal for small to mid-size buildings. The 4010ES scales from 250 to 1,000 points. The 4100ES supports up to 3,000 points with integrated voice evacuation for large or complex facilities. All three are networkable.
Can an Autocall panel replace my old conventional fire alarm panel?
Usually, yes. The Autocall 4007ES is cross-listed with most conventional detectors and supports programmable end-of-line resistors. It can often replace a conventional panel without rewiring the building, and you add addressable devices as areas are renovated.
Can an Autocall fire alarm release a fire suppression system?
Yes. The Autocall 4007ES and 4100ES are listed for multi-hazard suppression release, and the 4004R is a dedicated suppression release panel. In Alberta, a kitchen suppression system in a building with a fire alarm must activate the alarm when it discharges, and we wire and test that connection.
How often does an Autocall fire alarm system need to be inspected?
At least once a year, to CAN/ULC-S536, like any fire alarm system in Alberta. New or modified systems must also be verified to CAN/ULC-S537. Autocall's self-testing notification appliances and sensor status reports help make the annual inspection faster. What the annual inspection covers →
Can Autocall connect to my building automation system?
Yes. Autocall supports BACnet and Modbus. It can share information with building management and security systems and coordinate elevators, door holders, smoke dampers and pressurization fans during an alarm.
Our technicians at work
Real photos of our Calgary team on the job: installs, inspections and panel builds.






Planning a fire alarm install or upgrade?
Attach your drawings or a photo of your current panel model. We'll recommend the right Autocall system and quote it in writing.
- Written quote before any work
- Photos of every deficiency
- We book your next inspection and remind you