Kitchen fire suppression brands in CalgaryThe right technician for the system you have.
Defense Fire Protection sells, installs, inspects and recharges Kidde, Badger, Amerex, Buckeye, ProTex II and CaptiveAire kitchen fire suppression systems in Calgary. Every one needs an inspection every 6 months, and in Alberta only a technician trained by that manufacturer on that specific system may install or service it. Here is what each system is, how it works, and where it fits best.
- Kidde
- Badger
- Amerex
- Buckeye
- ProTex II
- CaptiveAire
- Autocall
Kitchen fire suppression systems compared
All six are wet chemical or water-based systems for hoods, plenums, ducts and cooking appliances. They differ in how they detect fire, how they install and where they fit best.
| System | Agent | Detection | Stand-out advantage | Great fit for |
|---|---|---|---|---|
| Kidde WHDR | APC wet chemical, stored pressure | Fusible alloy or thermo-bulb links, XV control | Fewer nozzles and flow points; listed from -18°C to 49°C | Restaurants, food trucks, concession trailers |
| Badger Range Guard | Karbaloy wet chemical, stored pressure | Mechanical links or electric Fenwal thermostats | Gauge on every cylinder, foil-sealed nozzles, 3-year warranty | Full-service restaurants, institutional kitchens |
| Amerex KP | Wet chemical | Fusible links, mechanical release | Appliance-specific coverage, typically lower initial cost | Smaller lines, budget-conscious installs |
| Buckeye Kitchen Mister | Misting wet chemical | Links on Buckeye Shielded Cable | No conduit or corner pulleys: faster, cleaner installs | Retrofits and system replacements |
| ProTex II | Wet chemical | Fusible links, mechanical release | UL and ULC listed; compatible with ProTex 2000 | Existing ProTex sites, standard hood lines |
| CaptiveAire CORE | Water-based (surfactant), plumbed to building water | Electronic thermal sensors on a supervised loop | Continuous water supply; factory-integrated with CaptiveAire hoods | New builds with CaptiveAire hood packages |
Every system above is listed to UL 300 and/or ULC/ORD-C1254.6, the standards Alberta requires for commercial kitchen fire suppression. See what Alberta requires.
Kidde WHDR wet chemical fire suppression
The Kidde WHDR is a pre-engineered, stored-pressure wet chemical system for hoods, plenums, ducts and cooking appliances. Its cylinders are factory-filled with Kidde APC agent and pressurized with nitrogen, and come in five sizes, so the system can be matched closely to your cook line. Kidde's XV control system provides automatic protection 24/7, with a manual remote release for staff.
Advantages
- Fewer discharge nozzles and flow points than many competing systems, which means less installation time and cost.
- UL and ULC listed from -18°C to 49°C (0°F to 120°F). That suits Calgary food trucks and concession trailers.
- Easy-to-read pressure gauge on every cylinder, for instant readiness checks.
- APC agent knocks flames down fast, cools surfaces and prevents re-ignition.
- Meets UL 300 and ULC/ORD-C1254.6, and complies with NFPA 17A and NFPA 96.
Key Kidde parts we service
WHDR cylinder and valve assemblies (WHDR-125 to WHDR-600) · system valve actuator (SVA) · XV control system · fusible alloy or thermo-bulb detectors · APC agent nozzles · manual remote release · automatic gas shut-off valve · micro switch
Badger Range Guard wet chemical fire suppression
Badger Range Guard is a pre-engineered, fixed-pipe wet chemical system for cooking appliances, hoods, plenums and ductwork. It uses Range Guard Karbaloy, a potassium-salt agent that turns burning grease into a smothering foam layer (saponification) and stops re-flash while the oil cools. Badger requires its systems to be supplied, installed and maintained by a factory-authorized Range Guard distributor.
Advantages
- Every cylinder has a visual pressure gauge with its own shield. Badger doesn't use burst discs to seal the discharge outlet.
- Nozzles have built-in strainers and replaceable foil-seal caps, with type rings machined into the body so the right nozzle is always on the right appliance.
- Mechanical actuation with thermo-bulb or fusible links needs no outside power. Electric actuation uses Fenwal Detect-A-Fire thermostats on a listed releasing panel.
- The control head micro switch drives the alarm and equipment shutdown, and every cylinder on one hazard discharges together.
- Three-year manufacturer warranty, ISO 9001 manufacturing, and UL 300 / ULC/ORD-C1254.6 listings.
Badger Industry Guard for spray booths: we also service Badger Industry Guard dry chemical systems for industrial hazards and vehicle paint spray booths. See paint booth fire suppression.

Key Badger parts we service
RG Series cylinder and valve assemblies · Karbaloy agent · system valve actuators · mechanical and electric control heads · thermo-bulb and fusible links · Fenwal Detect-A-Fire thermostats · foil-seal nozzle caps and strainers · Schedule 40 black steel and stainless distribution piping
Amerex KP restaurant fire suppression
The Amerex KP is a pre-engineered wet chemical restaurant system tested and listed to UL 300. It uses appliance-specific nozzle coverage, so each fryer, griddle or char broiler gets the protection it needs and nothing extra.
Advantages
- Appliance-specific coverage that typically means a lower initial cost.
- Designed, installed, maintained and recharged to the Amerex KP manual, which our technicians work from.
- Amerex also makes a full line of portable extinguishers, including K-class units, that we stock for your kitchen. See fire extinguisher service.
Buckeye Kitchen Mister fire suppression
The Buckeye Kitchen Mister is a wet chemical system that uses misting technology to knock down cooking oil and grease fires. Its simple design removes many common installation errors, and it's our go-to for replacing failed or non-compliant systems. We recently replaced a failing ANSUL system in a Calgary kitchen with a Buckeye Kitchen Mister after a Calgary Fire Department shutdown.
Advantages
- Approved for Buckeye Shielded Cable, so there's no conduit or corner pulleys on system inputs and outputs. Installs are faster and cleaner, with fewer places for the detection line to bind.
- Only one anchor bracket in the hood, which makes hood cleaning easier.
- BFR-5, BFR-10, BFR-15 and BFR-20 cylinders, rated by flow points, for flexible configurations.
- The SRM-D dual control head can actuate up to five agent cylinders with a nitrogen actuation cartridge.
- Made in the USA by Buckeye Fire Equipment, a fire equipment manufacturer since 1968.
Why a modified or mixed-brand system gets replaced, not patched →
ProTex II restaurant fire suppression
ProTex II, made by Heiser, is a pre-engineered wet chemical system built specifically for restaurant cooking-area fires. It provides automatic actuation plus manual actuation from a remote pull station. It is listed by Underwriters Laboratories and by Underwriters Laboratories of Canada (ULC).
Advantages
- UL and ULC listed, and designed to NFPA 96 and NFPA 17A.
- Several cylinder sizes cover anything from a short hood to a long cook line.
- ProTex II and ProTex 2000 systems are compatible, which makes upgrades at existing ProTex sites simpler.
- Stainless steel scissor linkage and fusible link options.
CaptiveAire CORE fire protection
CORE is CaptiveAire's own kitchen fire suppression system, built into its hood packages. Unlike traditional tank systems, CORE is water-based (with a surfactant) and plumbed into the building's water supply. It detects fire electronically, not with fusible links. It is listed to UL 300 and ULC/ORD-C1254.6.
Advantages
- Water supply doesn't run out the way a tank does. On activation, a timer keeps the water spray running for 30 minutes.
- Electronic thermal sensors and pull stations sit on a supervised loop with built-in redundancy and fault detection, so problems show up before a fire.
- When the system fires, gas and electric supply to the cook line shut off and the control panel alarms.
- Factory-integrated with the CaptiveAire hood's utility cabinet and pre-wired controls: one package, one supplier.
What if my system is ANSUL or another brand?
We confirm what is installed first. ANSUL and mixed-brand systems are replaced with Kidde, Badger, Amerex or Buckeye. More generally, if your current system isn't UL 300 or ULC/ORD-C1254.6 compliant, parts are unavailable, or it has been modified with mixed-brand parts, we'll quote a full replacement with one of our brands.
We often use the Buckeye Kitchen Mister for replacements because it installs quickly. On a recent Calgary job we replaced a failing ANSUL system with a Buckeye Kitchen Mister after a Calgary Fire Department shutdown. Not sure what you have? Send us a photo of the label and we'll tell you.
Why does the brand on your system decide who can service it?
Because Alberta's fire code says a technician may only install, test or maintain a kitchen suppression system they are trained on by that manufacturer, or hold the approved SAIT certificate for. Training on one brand doesn't carry over to another. Mixing parts between brands, like a Kidde cylinder on a Badger control head, voids the system's listing (read the Kidde + Badger case). Defense Fire Protection covers six brands, so the right technician shows up with the right parts.
Ready to book? See how a kitchen hood suppression inspection works.
Fire suppression brand questions
Which kitchen fire suppression brands can Defense Fire Protection service in Calgary?
Kidde, Badger, Amerex, Buckeye, ProTex II and CaptiveAire. We sell, install, inspect and recharge all six across Calgary, Airdrie, Chestermere, Cochrane and Okotoks.
What's the best kitchen fire suppression system for a new restaurant?
It depends on your hood, appliance line-up and budget. If you're buying a CaptiveAire hood package, CORE comes integrated. For a standard hood, Kidde WHDR and Badger Range Guard are excellent all-rounders. Amerex KP is often the lowest-cost install. We recommend a system after looking at your kitchen plan.
Which suppression system is best for a food truck in Alberta?
One listed for wide temperature swings. The Kidde WHDR is UL and ULC listed from -18°C to 49°C and offers compact food-truck configurations. See food truck fire suppression.
Can you replace my old ANSUL or other system?
Yes. If your current system isn't UL 300 or ULC/ORD-C1254.6 compliant, parts are unavailable, or it has been modified with mixed-brand parts, we'll quote a full replacement with one of our six brands. We often use the Buckeye Kitchen Mister for replacements because it installs quickly.
Do you service Autocall systems that release kitchen suppression?
Yes. Autocall 4007ES and 4100ES panels are listed for suppression release control, and we connect, program and test suppression-to-alarm tie-ins. See our Autocall page.
Our technicians at work
Real photos of our Calgary team on the job: installs, inspections and panel builds.






Not sure which brand you have?
Attach a photo of your cylinder label or control head. We'll tell you what it is and book your next inspection.
- Written quote before any work
- Photos of every deficiency
- We book your next inspection and remind you